HP-AFS/1 Automatic Immunoassay System whole blood POCT Vitamin D analyzer CE ISO

Categories

HP-AFS/1 Automatic Immunoassay System whole blood POCT Vitamin D analyzer CE ISO

HP-AFS/1 Automatic Immunoassay System whole blood POCT Vitamin D analyzer CE ISO
HP-AFS/1 Automatic Immunoassay System whole blood POCT Vitamin D analyzer CE ISOHP-AFS/1 Automatic Immunoassay System whole blood POCT Vitamin D analyzer CE ISOHP-AFS/1 Automatic Immunoassay System whole blood POCT Vitamin D analyzer CE ISOHP-AFS/1 Automatic Immunoassay System whole blood POCT Vitamin D analyzer CE ISOHP-AFS/1 Automatic Immunoassay System whole blood POCT Vitamin D analyzer CE ISO
Categorieskit swab samples
ModelHP083
TypeImmunoassay System
Instrument classificationClass II
FunctionDisease Analysis
CertificateCE ISO
FOB portTianjin xingang
Terms of PaymentL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal
Update Time2022/5/24
Detail Information
HP-AFS/1 Automatic Immunoassay System whole blood POCT Vitamin D analyzer CE ISO
Quick Details
Model Number
HP-AFS/1
Origin
China
Instrument classification
Class II
Application
Hosipital
Function
Disease Analysis
Certificate
CE ISO
Language
English
Product Description
Product Name
HP-AFS/1 Immunoassay system
HP-AFS Specific Protein Analyzer

is made up of light absorption test module, scattered light test module, fluorescence test module, press components, data transmission interface and printer. And the absorption test module is made up of absorption light path unit, and light-absorption sensor part. The scattered light test module is made up of scattered light path unit and scattered light sensor part. It can utilize nephelometry, fluorescence and absorbency methodologies to test the protein quantitatively in the samples. The model of the instrument (HP-AFS/1) is defined by the number of the test channel.

Principle
1, Nephelometric test principle
—Rayleigh theory of Scattering
When the particle diameter is more than the wavelength of the incident light, the light basically scatters forward.
—Rayleigh-Debye/Mie theory of Scattering
When the particle diameter is less than the wavelength of the incident light, the light scatters in all directions evenly
2, Fluorescence test principle
3, Absorbency test principle
Technical
Nephelometry
Linear range
100~4000 NTU
Linear correlation coefficient≥0.99
RSD
RSD≤8%
Stability
The turbidity variation≤10%
Accuracy
Relative deviation≤10%
Fluorescence
Linear range
100~1600AU,
Linear correlation coefficient r≥0.99
RSD
RSD≤8%
Stability
Fluorescence variation≤15%
Accuracy
Relative deviation≤10%
Sensitivity
Detection limit is not more than 2.5μmol/L
Absorbency
Linear range
See attached table 1
RSD
RSD≤1%
Stability
The absorbency deviation is not more than 0.005 at 340nm position within 20min
Table 1
Linear range of absorbency
Linear range (A)
Deviation(%)
0.2~≤0.5
+5-5
>0.5~≤1.0
+4-4
>1.0~≤1.8
+2-2
Calibration
Parameters
Related Product
Similar product