Home / Products / Injection Therapy/Interventional Therapy / Intervention System / Implantable Artificial Organs /

Good quality Knee titanium prosthesis Primary knee joint prosthesis

Categories

Good quality Knee titanium prosthesis Primary knee joint prosthesis

Good quality Knee titanium prosthesis Primary knee joint prosthesis
Good quality Knee titanium prosthesis Primary knee joint prosthesisGood quality Knee titanium prosthesis Primary knee joint prosthesisGood quality Knee titanium prosthesis Primary knee joint prosthesisGood quality Knee titanium prosthesis Primary knee joint prosthesisGood quality Knee titanium prosthesis Primary knee joint prosthesis
CategoriesImplantable Artificial Organs
ModelSKI
TypeImplantable Artificial Organs
PropertiesImplant Materials & Artificial Organs
Licence NumberISO13485 / ISO9001
Instrument classificationClass III
International Test5 Million Cycles Wear Test
FOB portTianjin xingang
Terms of PaymentL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal
Update Time2021-10-26
Detail Information
Good quality Knee titanium prosthesis Primary knee joint prosthesis
Quick Details
Model NO.
SKI 
Origin
Tianjin, China
Application
Knee Replacement
Material
CoCrMo+UHMWPE
Certificate
CE/ISO:9001/ISO13485
OEM
Available
Packaging & Delivery
Packaging Details: Standard Packing
Port: Tianjin
SKI Primary TKA
Biomet Vanguard Knee titanium prosthesis Primary knee joint prosthesis




• Maximized bone preserved with Femoral A/P    
   increments in 2mm
• Surgical simplicity with complete component
   interchangablility
• Intercondylar milling technique reduces risk of    
   intraoperative fracture
• 145 degrees high flexion designre

Extended Cam
to realize high flexion

Patellar Release
to reduce tension of patellar tendon in deep flexion
German UHMWPE
All raw material of UHMWPE bearing were manufacturered in Germany, meeting the technical requirements in ISO 5834-Part 2 and ASTM F648
Minimized Bearing Wear
Mirror polished articular surface Ra 0.037μm
5 Million Cycles Wear Test at EndoLab® in Germany







EndoLab® knee simulater




A mean UHMWPE tibial insert wear rate of 5.79 mg per million cycles (SD 0.61 mg per million cycles) was determined after 5.0 million cycles. 
Biomet Vanguard Knee Primary knee joint prosthesis 
Intercondylar Milling





Reduces the risk of introperative fracture by dispersing the stress created by square corners

Dimension
Components
Spec.
A/P (mm
M/L(mm)
Femoral Condyle PS
1# L/R
55
59
2# L/R
57
61
3# L/R
59
64
4# L/R
61
66
5# L/R
63
68
6# L/R
66
71
7# L/R
68
73
8# L/R
70
75
9# L/R
72
78
Tibial Tray
A/P (mm)
M/L(mm)
MATCH WITH Tibial Bearing
1#
38
59
1#  H: 8/10/12/14 mm
2#
41
63
2#   H: 8/10/12/14 mm
3#
43
67
4#
46
71
4#  H: 8/10/12/14 mm
5#
48
75
6#
51
79
6#  H: 8/10/12/14 mm
7#
53
83
About JUST HUAJIAN

Product Line
Imported Raw Material
Radial separation value for sphericity
SKI Primary artificial prosthetic total replacement TKA knee implants
Tests by The 3rd Party Testing Agencies
5 Million Cycles Wear Teat for TKR and THR System
Please send your message to us
*Email
Name
Tel
*Title
*Content
Address
Categories
KEEP IN TOUCH
Please send your message to us
*Email
Name
Tel
*Title
*Content
Address
Contact us
subscription